This industrial handheld controller is a compact operator terminal and industrial control panel: a human-machine interface with a graphic display and industrial membrane keypad, designed for machinery control in demanding environments. Built on RISC-V and FreeRTOS with RS485 communications, this industrial HMI is rated above IP55.
The unit integrates a graphic display, membrane keypad and RS485 communications, so system information can be viewed, operating modes selected, commands entered and remote equipment controlled from a single terminal.
It is built to operate in demanding environmental conditions, with a user interface designed to achieve a protection rating above IP55, providing resistance to dust and water ingress when the assembly is correctly installed.
Integrated HMI
The controller acts as a compact HMI (Human Machine Interface) for interaction between the operator and the control system.
The combination of display and keypad allows operating information to be shown and commands to be executed directly from the terminal, with no need for touchscreens or additional computer systems.
This architecture is especially well suited to machinery, positioning systems and equipment installed in industrial or outdoor environments.
Graphic display
The unit features a graphic display that presents relevant application information clearly.
The display can show operating states, parameters, positions, process values, configuration menus, diagnostic messages and alarm conditions.
Local processing updates the information received over RS485 and gives the operator an immediate view of the system status.
Membrane keypad
The membrane keypad provides a robust physical interface for controlling the equipment.
The keys can be assigned to navigation, selection, motion activation, speed changes, operation confirmation or specific functions.
Compared with a touch-only interface, a physical keypad makes the terminal easier to use in applications that require a direct, clearly identifiable response from the operator.
RISC-V architecture
The system is based on a RISC-V architecture that manages the graphical interface, keypad, communications and operating logic of the terminal.
Local processing interprets user actions, updates the display and handles data exchange with the main controller of the installation.
This architecture provides a flexible embedded platform for developing user interfaces tailored to different applications.
FreeRTOS operating system
The firmware uses FreeRTOS as its real-time operating system.
The application can be structured as independent tasks for display management, keypad scanning, RS485 communications, diagnostics and operational monitoring.
This architecture supports deterministic behaviour and a fast response to operator actions.
RS485 communications
Communication between the controller and the main system is via RS485, an interface particularly well suited to industrial applications.
RS485 provides robust communications over longer distances than typical local electronic interfaces and offers good immunity to electrical interference.
Through this link, the terminal can receive status information and transmit the commands entered by the operator.
The integrated cable provides a direct connection between the controller and the controlled equipment, simplifying installation.
Environmental protection
The terminal is designed for applications where demanding environmental conditions may be present.
A sealed enclosure and membrane keypad make it possible to achieve an interface rated above IP55, suitable for environments with dust, humidity or exposure to water.
This allows the controller to be used both in industrial installations and outdoor applications, always in accordance with the specific certification conditions of the product.
Applications
The controller is intended for industrial machinery, positioning systems, motion control, maintenance equipment, orientation systems, outdoor installations and applications requiring a rugged wired HMI.
Its combination of RISC-V, FreeRTOS, graphic display, membrane keypad, RS485 and environmental protection makes it possible to develop dedicated terminals tailored to the needs of each machine or installation.
Technical specifications
| Type | Industrial handheld controller / HMI |
|---|---|
| Architecture | RISC-V |
| Operating system | FreeRTOS |
| Visual interface | Graphic display |
| User interface | Membrane keypad |
| Communications | RS485 |
| Connection | Wired |
| Environmental protection | >IP55 |
| Processing | Local |
| Applications | Industrial control and machinery |